| TECHNICAL DATA OF THE SICL 10 CONDUCTOR BAR | ||
| Housing material/-colours: | PVC/blue (phase), green (earth) | |
| Standard length: | 6000 mm | |
| Number of poles: | Any number | |
| Phase-/suspension distance: | 15 mm/max. 800 mm | |
| Voltage UN: | 690 V AC | |
| Amperage (100% duty cycle at 35˚C) | 100 A (copper)/ 10A (stainless steel) | |
| Conductor bar cross section | 25 mm² | |
| Conductor material | C=copper/N=Niro (stainless steel) | |
| Ambient/housing temperature | -30˚C up to + 90˚C | |
| Travel speed | 400 m/min | |
| Protection class (DIN VDE 0470 p.1/EN 60529) | IP23 | |
| Electrical data | Dielectric strength (DIN 5381) | >22.4 kV/mm |
| Tracking (IEC 60112) | CTI 600-1.1 | |
| Special contact resistance (IEC 60093) | >8x10 15 Ohm x cm | |
| Surface resistance (IEC 60093) | >2x10 13 Ohm x cm | |
| Smalles curve radius | > 300 mm (horizontal/vertical) | |
| Operation-/application area | Inndors | |
| Fire protection equipment | UL94/V0 (Flame retardant/self-extinguishing) | |
| Protection from accidental conract | VDE 0470/VDE 0100 | |
| Air-and leakage distances | VDE 0110 | |
| Resistant against | fuel, mineral oil, greases, sodium hydroxide(<25%) hydrochloric acid (concentrated), sulphuric acid (<50%) |
|